The Omron 7250 is a digital blood pressure monitor designed for upper arm measurement, featuring IntelliSense technology for accurate and comfortable readings, irregular heartbeat detection, hypertension indicator, memory storage for multiple users, and a large LCD display with date/time function. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with D-ring, AC adapter, Storage case, Instruction manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically inflates to optimal pressure for accurate reading |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat symbol during measurement |
| Hypertension Indicator | Displays warning symbol if reading exceeds WHO guidelines |
| Multi-User Memory | Stores up to 100 readings for two users with date/time stamp |
| Large LCD Display | Easy-to-read backlit display with clear icons |
| Automatic Power Off | Conserves battery life by turning off after 1 minute of inactivity |
| Date/Time Function | Built-in clock for tracking measurement history |
| Comfort Inflation | Adjusts inflation based on systolic pressure for comfort |
| Body Movement Detection | Alerts if movement is detected during measurement |
| Cuff Wrapping Guide | Ensures proper cuff placement for accurate results |
Unpack and verify all components are present.
WARNING! Do not use if any components are damaged. Contact customer service for replacement.
Prepare the monitor for first use.
CAUTION! Use only specified AC adapter. Do not mix old and new batteries.
Front Panel: START/STOP button, USER button, SET button, UP/DOWN buttons.
Display Symbols: Systolic/Diastolic values, Pulse rate, User indicator (1/2), Memory full, Irregular heartbeat, Hypertension, Body movement, Low battery, Date/Time, Cuff wrapping guide.
Settings: Date/Time setup, Memory recall, Unit selection (mmHg/kPa), Average reading display (last 3 readings per user).
For accurate results, follow these steps carefully.
Tip: Take measurements at same time each day for consistent tracking.
Stores up to 100 readings per user with date/time stamp.
Note: Memory full indicator appears when 100 readings are stored per user.
Interpretation of readings and symbols.
| Symbol | Meaning | Action |
|---|---|---|
| Irregular Heartbeat | Detected irregular pulse rhythm | Consult healthcare provider if frequent |
| Hypertension Indicator | Systolic ≥135 or Diastolic ≥85 mmHg | Monitor regularly, consult doctor |
| Body Movement | Movement detected during measurement | Remain still and retake measurement |
| Error Symbol | Measurement error occurred | Check cuff placement and retry |
Normal Ranges: Systolic: 90-119 mmHg, Diastolic: 60-79 mmHg, Pulse: 60-100 bpm.
Remove batteries before cleaning. Use soft, dry cloth only; do not use liquids or solvents.
CAUTION! Do not immerse in water. Do not disassemble unit.
FDA Cleared: K number [insert K number]. CE Marked: Medical Device Directive 93/42/EEC. Manufactured by: Omron Healthcare Co., Ltd., Kyoto, Japan. Distributed by: Omron Healthcare, Inc., Lake Forest, IL USA. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries with new alkaline batteries |
| Error E1 displayed | Cuff not properly attached | Check cuff connection, ensure tube is fully inserted |
| Error E2 displayed | Cuff over-inflated | Deflate completely and restart measurement |
| Inconsistent readings | Improper cuff position | Ensure cuff is at heart level, sit correctly |
| Memory not saving | Memory full | Clear memory or select different user |
| Unit turns off during measurement | Low batteries | Replace batteries or use AC adapter |
| Inaccurate readings | Unit needs calibration | Have unit checked by authorized service center |
Reset: Remove batteries for 5 minutes, then reinsert to reset unit.
Service: 1-800-634-4350; www.omronhealthcare.com