The Omron 5250 is a professional-grade blood pressure monitor designed for accurate, at-home blood pressure and pulse rate measurement. It features IntelliSense technology for comfortable inflation, a large LCD display with backlight, hypertension indicator, irregular heartbeat detection, memory storage for multiple users, and AC adapter compatibility. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatically adjusts inflation for a comfortable, accurate reading |
| Large LCD Display with Backlight | Easy-to-read results in various lighting conditions |
| Hypertension Indicator | Displays a warning symbol if blood pressure is elevated |
| Irregular Heartbeat Detection | Detects and displays an icon for pulse irregularities during measurement |
| Dual User Memory | Stores up to 100 readings for each of two users |
| Date & Time Stamp | Records the date and time with each measurement |
| AC Adapter Port | For powering the device without batteries |
| START/STOP Button | Initiates and stops the measurement process |
| MEMORY Button | Accesses stored readings |
| USER Button | Selects between User 1 and User 2 for memory |
Unpack and verify all items are present.
WARNING! Do not use if any item is damaged. Keep plastic bags away from children to avoid suffocation.
Prepare the monitor for first use.
CAUTION! Use only the specified AC adapter. Incorrect power source may damage the unit.
Front Panel: START/STOP, MEMORY, USER, SET. Display Icons: Systolic/Diastolic pressure, Pulse rate, User indicator, Hypertension symbol, Irregular heartbeat symbol, Battery indicator, Date/Time.
Button Functions: START/STOP: Begins inflation and measurement. MEMORY: Recalls stored readings. USER: Toggles between User 1 and User 2. SET: Sets date, time, and other parameters.
Display Readings: Shows systolic pressure (top), diastolic pressure (middle), and pulse rate (bottom). Backlight activates during operation and turns off automatically.
For the most accurate results, sit quietly for 5 minutes before measuring.
Tip: Take measurements at the same time each day for consistent tracking.
Stores and recalls past readings with date and time.
WARNING! Clearing memory is permanent. Ensure you have recorded any needed data.
Unplug AC adapter or remove batteries before cleaning. Wipe main unit and cuff with a soft, dry cloth. Do not immerse in water or use harsh chemicals.
CAUTION! Do not wash the cuff. Do not disassemble the unit. Store in the provided case in a cool, dry place away from direct sunlight and extreme temperatures.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. This equipment meets the requirements of EN 1060-4:2004 (Non-invasive sphygmomanometers). Manufactured for Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact customer service at 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Display is blank | Dead batteries/power | Replace batteries or connect AC adapter. Ensure power is secure. |
| Error Code "E" appears | Cuff not attached/leaking | Ensure cuff tube is connected properly. Check cuff for leaks or damage. |
| Irregular Heartbeat symbol flashes | Pulse irregularity detected | Remain still and retake measurement. If persistent, consult a physician. |
| Inaccurate reading | Incorrect posture/cuff position | Ensure proper sitting posture and cuff placement at heart level. |
| Memory not storing | Memory full/wrong user selected | Clear old readings or switch to the correct user with USER button. |
Reset: Remove batteries/unplug adapter for 5 minutes to perform a soft reset.
Service: 1-800-634-4350; www.omronhealthcare.com