Omron 5250 User Manual

The Omron 5250 is a professional-grade blood pressure monitor designed for accurate, at-home blood pressure and pulse rate measurement. It features IntelliSense technology for comfortable inflation, a large LCD display with backlight, hypertension indicator, irregular heartbeat detection, memory storage for multiple users, and AC adapter compatibility. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Package Contents 3. First-Time Setup 4. Specifications 5. Controls and Display 6. Taking a Measurement 7. Memory Function 8. Care & Maintenance 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Main Unit, Arm Cuff, AC Adapter, Instruction Manual, Storage Case.

FeatureDescription
IntelliSense TechnologyAutomatically adjusts inflation for a comfortable, accurate reading
Large LCD Display with BacklightEasy-to-read results in various lighting conditions
Hypertension IndicatorDisplays a warning symbol if blood pressure is elevated
Irregular Heartbeat DetectionDetects and displays an icon for pulse irregularities during measurement
Dual User MemoryStores up to 100 readings for each of two users
Date & Time StampRecords the date and time with each measurement
AC Adapter PortFor powering the device without batteries
START/STOP ButtonInitiates and stops the measurement process
MEMORY ButtonAccesses stored readings
USER ButtonSelects between User 1 and User 2 for memory

Package Contents

Unpack and verify all items are present.

  1. Omron 5250 Blood Pressure Monitor (Main Unit).
  2. Arm Cuff (22-32 cm circumference).
  3. AC Adapter.
  4. Instruction Manual (this document).
  5. Storage Case.
  6. 4 x AA Batteries (optional/pre-installed in some regions).

WARNING! Do not use if any item is damaged. Keep plastic bags away from children to avoid suffocation.

First-Time Setup

Prepare the monitor for first use.

  1. Insert Batteries: Open battery compartment, insert 4 AA batteries observing polarity, or connect the AC adapter.
  2. Set Date & Time: Press the SET button and use the MEMORY button to adjust values. Press START/STOP to confirm.
  3. Attach the Cuff: Ensure the cuff tube is plugged securely into the left side of the main unit.
  4. Select User: Press the USER button to choose User 1 or User 2 for memory storage.

CAUTION! Use only the specified AC adapter. Incorrect power source may damage the unit.

Specifications

Controls and Display

Front Panel: START/STOP, MEMORY, USER, SET. Display Icons: Systolic/Diastolic pressure, Pulse rate, User indicator, Hypertension symbol, Irregular heartbeat symbol, Battery indicator, Date/Time.

Button Functions: START/STOP: Begins inflation and measurement. MEMORY: Recalls stored readings. USER: Toggles between User 1 and User 2. SET: Sets date, time, and other parameters.

Display Readings: Shows systolic pressure (top), diastolic pressure (middle), and pulse rate (bottom). Backlight activates during operation and turns off automatically.

Taking a Measurement

For the most accurate results, sit quietly for 5 minutes before measuring.

  1. Sit Correctly: Sit on a chair with feet flat on the floor, back supported.
  2. Apply Cuff: Place cuff on bare upper arm 1-2 cm above elbow. Align artery marker with brachial artery. Secure snugly.
  3. Position Arm: Rest arm on a table so the cuff is at heart level.
  4. Start Measurement: Press START/STOP. The cuff will inflate automatically.
  5. Remain Still: Do not move or talk during measurement.
  6. Read Results: Systolic, diastolic, and pulse rate display when measurement is complete. Cuff deflates automatically.
  7. Interpret Symbols: Note hypertension or irregular heartbeat icons if they appear.

Tip: Take measurements at the same time each day for consistent tracking.

Memory Function

Stores and recalls past readings with date and time.

  1. View Memory: Press MEMORY button. The most recent reading displays.
  2. Scroll: Press MEMORY again to scroll through previous readings in reverse chronological order.
  3. Switch Users: Press USER button to view memory for the other user.
  4. Clear Memory: To clear all readings for the current user, press and hold the MEMORY button for 5 seconds while in memory mode. "CLr" will flash.

WARNING! Clearing memory is permanent. Ensure you have recorded any needed data.

Care & Maintenance

Unplug AC adapter or remove batteries before cleaning. Wipe main unit and cuff with a soft, dry cloth. Do not immerse in water or use harsh chemicals.

CAUTION! Do not wash the cuff. Do not disassemble the unit. Store in the provided case in a cool, dry place away from direct sunlight and extreme temperatures.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. This equipment meets the requirements of EN 1060-4:2004 (Non-invasive sphygmomanometers). Manufactured for Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact customer service at 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
Display is blankDead batteries/powerReplace batteries or connect AC adapter. Ensure power is secure.
Error Code "E" appearsCuff not attached/leakingEnsure cuff tube is connected properly. Check cuff for leaks or damage.
Irregular Heartbeat symbol flashesPulse irregularity detectedRemain still and retake measurement. If persistent, consult a physician.
Inaccurate readingIncorrect posture/cuff positionEnsure proper sitting posture and cuff placement at heart level.
Memory not storingMemory full/wrong user selectedClear old readings or switch to the correct user with USER button.

Reset: Remove batteries/unplug adapter for 5 minutes to perform a soft reset.

Service: 1-800-634-4350; www.omronhealthcare.com