The Omron 3 Series is a line of advanced blood pressure monitors designed for home use, featuring IntelliSense technology for accurate readings, one-touch operation, hypertension detection, irregular heartbeat detection, multi-user memory, and body movement detection. Powered by 4 AA batteries or AC adapter. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Package Contents 3. Getting Started 4. Specifications 5. Controls and Display 6. Taking a Measurement 7. Memory Function 8. Understanding Results 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with LCD display, Arm Cuff, AC adapter, Instruction manual, Storage case.

FeatureDescription
IntelliSense TechnologyAutomatic inflation to optimal level for comfort and accuracy
One-Touch OperationSimple start/stop with single button
Hypertension IndicatorDisplays warning symbol if reading is high
Irregular Heartbeat DetectionDetects and displays irregular heartbeat during measurement
Multi-User MemoryStores up to 100 readings for two users
Body Movement DetectionAlerts if movement is detected during measurement
Date & Time StampRecords date and time of each reading
Average ReadingCalculates average of last three readings
AC Adapter PortFor optional AC power connection
Battery CompartmentHolds 4 AA batteries

Package Contents

Unpack and inspect all items. Contact retailer if anything is missing.

  1. Omron 3 Series Blood Pressure Monitor (Main Unit)
  2. Arm Cuff (22-32 cm circumference)
  3. AC Adapter
  4. Instruction Manual
  5. Storage Case
  6. 4 AA Batteries (may be included)

WARNING! Do not use if packaging is damaged or components appear defective. Keep out of reach of children.

Getting Started

Prepare monitor for first use.

  1. Insert batteries: Open compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter (optional): Plug into AC port and wall outlet.
  3. Set date and time: Press SET button, use arrows to adjust, press START/STOP to confirm.
  4. Apply cuff: Wrap cuff on bare upper arm 1-2 cm above elbow, align artery marker with brachial artery.
  5. Sit correctly: Sit with back straight, feet flat, arm supported at heart level.

CAUTION! Ensure cuff is properly positioned for accurate readings. Avoid measuring after exercise or eating.

Specifications

Controls and Display

Front Panel: START/STOP button, SET button, UP/DOWN arrows, Memory button.

Display Symbols: Systolic/Diastolic pressure, Pulse rate, Hypertension indicator, Irregular heartbeat symbol, Body movement icon, User indicator (1/2), Memory full, Low battery, Date/Time, Average value.

Settings: Date/Time setup, User selection, Memory review, Average calculation, Unit selection (mmHg/kPa).

Taking a Measurement

Follow steps for accurate reading.

  1. Sit quietly for 5 minutes before measuring.
  2. Wrap cuff properly on left arm (unless specified otherwise).
  3. Press START/STOP button to begin inflation.
  4. Remain still and quiet during measurement.
  5. Monitor will deflate automatically and display results.
  6. Results show systolic, diastolic, and pulse rate.
  7. Press START/STOP to turn off or wait 1 minute for auto-off.

Tip: Take measurements at same time each day for consistent tracking.

Memory Function

Stores readings for two users.

  1. Select user: Press SET to choose User 1 or User 2 before measurement.
  2. View memory: Press MEMORY button to scroll through stored readings.
  3. Average reading: Display shows average of last three readings for selected user.
  4. Clear memory: Hold SET and MEMORY buttons for 3 seconds to clear all data.

Note: Memory full indicator appears when 100 readings are stored per user.

Understanding Results

Interpret readings and symbols.

SymbolMeaningAction
Hypertension IndicatorSystolic ≥135 or Diastolic ≥85 mmHgConsult healthcare provider
Irregular Heartbeat SymbolDetected irregular rhythm during measurementRepeat measurement; if persistent, seek medical advice
Body Movement IconExcessive movement detectedRemain still and retake measurement
Error Codes (E1-E5)Cuff error, measurement error, etc.Refer to troubleshooting section

Normal Range: Systolic: <120 mmHg; Diastolic: <80 mmHg.

Care & Maintenance

Clean monitor with soft, dry cloth. Do not immerse in water or use solvents.

  1. Remove batteries if not using for extended period.
  2. Store in cool, dry place away from direct sunlight.
  3. Inspect cuff regularly for wear or damage.
  4. Replace batteries when low battery indicator appears.

CAUTION! Do not disassemble unit. Avoid extreme temperatures and humidity.

Regulatory Information

FDA Cleared: For over-the-counter home use. CE Marked: Complies with European Medical Device Directive. Manufactured by Omron Healthcare Co., Ltd. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace batteries; ensure proper insertion.
Error E1Cuff not attached properlyReconnect cuff; ensure tight connection.
Error E2Cuff over-inflatedDeflate cuff and restart measurement.
Inaccurate readingImproper cuff positionReposition cuff 1-2 cm above elbow.
Memory not savingMemory fullClear memory or switch to other user.
Irregular heartbeat symbolArrhythmia detectedTake multiple readings; consult doctor if consistent.

Reset: Remove batteries for 1 minute to reset unit.

Service: 1-800-634-4350; www.omronhealthcare.com