The Omron Blood Pressure Monitor is a clinically validated, automatic upper arm device designed for accurate at-home blood pressure measurement. It features IntelliSense technology for comfortable inflation, hypertension detection indicators, irregular heartbeat detection, memory storage for multiple users, a large backlit display, and one-touch operation. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Precautions 3. Getting Started 4. Specifications 5. Parts and Controls 6. Proper Measurement Technique 7. Understanding Your Readings 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with display, Arm cuff, AC adapter, Storage case, Instruction manual.

FeatureDescription
IntelliSense TechnologyAutomatically adjusts inflation for comfortable measurement
Hypertension IndicatorDisplays warning symbol if reading is high
Irregular Heartbeat DetectionDetects pulse irregularities during measurement
Dual User MemoryStores up to 100 readings for two users
One-Touch OperationSimple START/STOP button
Backlit DisplayEasy-to-read LCD screen
Date & Time StampRecords measurement time for tracking
AVERAGE ModeCalculates average of last 3 readings
AC Adapter/BatteryPowered by 4 AA batteries or included AC adapter
World Health Organization (WHO) IndicatorColor-coded display for result classification

Safety Precautions

Read all instructions before use. Consult your physician for interpretation of readings.

  1. Do not use on infants, small children, or persons who cannot express themselves.
  2. Do not use during bathing or showering.
  3. Do not use on an arm with an intravenous drip or surgical wound.
  4. Do not inflate cuff when not wrapped around arm.
  5. Keep device away from children and pets.

WARNING! This device is for measuring blood pressure only, not for diagnosis. Consult your doctor for medical advice.

Getting Started

Prepare the monitor for first use.

  1. Insert batteries: Open battery compartment, insert 4 AA batteries observing polarity.
  2. Connect AC adapter: Plug into DC jack on side of unit and into wall outlet.
  3. Set date and time: Press and hold CLOCK button, use SET to adjust.
  4. Apply cuff: Wrap cuff around bare upper arm 1-2 cm above elbow.
  5. Position arm: Rest arm on table with cuff at heart level.

CAUTION! Ensure cuff is properly sized and positioned for accurate readings.

Specifications

Parts and Controls

Front Panel: START/STOP button, MEMORY button, CLOCK button, SET button, Display screen.

Display Symbols: Systolic pressure, Diastolic pressure, Pulse rate, User indicator (1/2), Memory full, Battery low, Irregular heartbeat, Hypertension, WHO classification, Date/Time, Average.

Buttons: START/STOP begins/stops measurement. MEMORY recalls stored readings. CLOCK sets date/time. SET navigates settings.

Proper Measurement Technique

For accurate results, follow these steps each time:

  1. Sit quietly for 5 minutes before measuring.
  2. Sit in a chair with feet flat on floor and back supported.
  3. Apply cuff to bare upper arm (left arm recommended).
  4. Position cuff at heart level (elbow level with heart).
  5. Press START/STOP button.
  6. Remain still and quiet during inflation and measurement.
  7. Read results when measurement completes.
  8. Record reading in log if desired.

Tip: Take measurements at the same time each day for consistent tracking.

Understanding Your Readings

The monitor displays systolic pressure (top number), diastolic pressure (bottom number), and pulse rate.

CategorySystolic (mmHg)Diastolic (mmHg)WHO Indicator
NormalBelow 120Below 80Green
Prehypertension120-13980-89Yellow
Hypertension Stage 1140-15990-99Orange
Hypertension Stage 2160 or higher100 or higherRed

Irregular Heartbeat Symbol: Appears if irregular pulse detected during measurement. Consult physician if frequent.

Care & Maintenance

Clean with soft, dry cloth. Do not use alcohol, benzene, or abrasive cleaners.

  1. Store in carrying case when not in use.
  2. Remove batteries if not using for extended period.
  3. Do not expose to extreme temperatures, humidity, dust, or direct sunlight.
  4. Do not drop or subject to strong shocks.
  5. Replace cuff if torn or damaged.

CAUTION! Never immerse unit in water or other liquids.

Regulatory Information

FDA Cleared: This device complies with FDA standards for home blood pressure monitors. CE Marked: Meets European medical device directives. Manufactured by Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayDead batteriesReplace all 4 batteries; ensure proper polarity.
Error code E1Cuff not wrapped properlyRewrap cuff; ensure tube is connected securely.
Error code E2Measurement errorRemain still; retake measurement.
Inconsistent readingsImproper positioningEnsure cuff at heart level; sit quietly before measuring.
Cuff doesn't inflateAir leakCheck tube connections; replace cuff if damaged.
Memory full100 readings storedDelete old readings or switch to other user memory.

Reset: Remove batteries for 5 minutes to reset device.

Service: 1-800-634-4350; www.omronhealthcare.com