The HJ 112 Omron is a digital blood pressure monitor designed for home use, featuring IntelliSense technology for accurate readings, one-touch operation, hypertension indicator, irregular heartbeat detection, memory storage for multiple users, adjustable cuff, large LCD display, and battery/power adapter operation. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.
Key components: Main unit with LCD display, Arm cuff with D-ring, AC adapter, Storage case, Instruction manual.
| Feature | Description |
|---|---|
| IntelliSense Technology | Automatic inflation to optimal level for accurate readings |
| One-Touch Operation | Simple START/STOP button for easy use |
| Hypertension Indicator | Displays warning symbol if blood pressure is high |
| Irregular Heartbeat Detection | Detects and displays irregular heartbeat during measurement |
| Memory Storage | Stores up to 60 readings for multiple users |
| Adjustable Cuff | Fits arm circumferences 22-32 cm (9-13 inches) |
| Large LCD Display | Easy-to-read results with date/time stamp |
| Power Options | 4 AA batteries or AC adapter (included) |
| Automatic Power Off | Conserves battery life when not in use |
| WHO Classification Indicator | Shows blood pressure classification according to WHO standards |
Read all instructions before use. For accurate measurements and safe operation.
WARNING! This device is for home use only, not for clinical diagnosis. Consult healthcare professional for medical decisions.
Prepare device and yourself for accurate measurement.
CAUTION! Ensure cuff is not too tight or loose. Tube should run down center of arm.
Front Panel: START/STOP button, MEMORY button, USER button (User 1/User 2), SET button.
Display Symbols: Systolic/Diastolic pressure, Pulse rate, User indicator, Memory full, Battery low, Irregular heartbeat symbol, Hypertension indicator, WHO classification, Date/Time, Error codes.
Settings: Date/Time setup (press SET to enter setting mode), User selection (User 1/User 2), Memory review (press MEMORY to scroll through stored readings).
Follow proper procedure for accurate results.
Tip: Take measurements at same time each day for consistent tracking. Avoid measurements when stressed or anxious.
Store and review past measurements.
Note: Each user has separate 60-reading memory. Date and time stored with each reading.
Proper care ensures device longevity and accuracy.
CAUTION! Do not immerse unit in water. Do not wash cuff in washing machine. Avoid extreme temperatures.
FDA Cleared: For over-the-counter home use. CE Marked: Meets European medical device directives. Manufactured according to ISO 13485 quality standards. Copyright © Omron Healthcare, Inc. For support, visit www.omronhealthcare.com or contact 1-800-634-4350.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace all 4 batteries; ensure proper insertion. |
| Error code E1 | Cuff not attached properly | Check cuff connection; reattach securely. |
| Error code E2 | Cuff pressure error | Ensure cuff not twisted; reposition on arm. |
| Error code E3 | Pulse detection error | Remain still during measurement; reposition cuff. |
| Inconsistent readings | Improper posture or movement | Sit correctly with arm at heart level; avoid talking/moving. |
| Cuff does not inflate | Blocked air tube or leak | Check tube for kinks; ensure tight connections. |
| Memory not working | Battery removal | Memory clears when batteries removed; replace without delay. |
Reset: Remove batteries for 1 minute to reset device.
Service: 1-800-634-4350; www.omronhealthcare.com